| Format : |
CP-200TP |
| Measuring system : |
pH: Glass electrode measurement method
ORP: Metal electrode measurement method |
| Measurement range : |
pH 0 14 : Resolution 0.01 pH
ORP±200mV : Resolution 1mV |
| Reproducibility : |
pH ±0.05 ORP ±5mV |
| Transmission output : |
DC4 20mA Input/output isolated, Maximum load resistance 500Ω |
| Transmission output range : |
pH : 0-14, 0-10, 0-8, 2-12, 3-11, 4-14, 4-10, 6-14
ORP: ±1400mV, ±1000mV, ±700mV, ±350mV, - 1000-0mV,
0-1000mV, ±2000mV, 0-700mV (Changeable with internal DIG switch) |
| Adjustment function : |
1c contact output Independent 2CH
Capacity: AC250V, 3A max (Resistance load) |
| Control operation : |
Proportional time sharing ON/OFF Control: Upper limit operation (H) and lower limit operation (L) (Changeable with internal DIP switch)
Upper/lower limit setting range :
pH meter 0.00-14.00 pH, ORP meter 0- ±200mV
Proportional band :
pH meter 0.00 4.00pH (ON/OFF control when set to 0.00)
ORP meter 0 400mV (ON/OFF control when set to 0)
Cycle : 5-300 seconds |
| Calibration function [pH only] : |
2-point automatic calibration or manual calibration (Select change using internal DIP switch) |
| Additional function : |
Each error message type
1. Calibration error (Asymmetrical potential, sensitivity, response rate error, standard solution error) [pH only]
2. Electrode diagnostic error Temperature sensor short, Temperature sensor tripped [pH only]
3. Measurement out-of-range error Full scale over/under Hold contact input during cleaning (1a no-voltage contact input) [pH only] Warning output canceled when contact is ON Continuous transmission output during calibration or cleaning, Hold (Previous value hold, arbitrary hold) (Changeable with internal DIP switch) Measured value shift function pH: ±2.00 pH ORP: ±200mV Input filter time constant switching function Time constant: None/Approx. 7 seconds (Changeable with internal DIP switch) |
| Temperature compensation element [pH only] : |
500Ω (25°C) Other Compatible with 6.8kΩ (25°C), 350Ω (25°C), 1kΩ (0°C), or 10kΩ (25°C) (Changeable with internal DIP switch) |
| Temperature compensation range [pH only] : |
0-100°C) (For pH meter) |
| Ambient temperature & humidity : |
-5-50°C, Less than 85% RH |
| Power : |
AC100 115V 50/60Hz 7VA or AC200 240V 50/60Hz 7VA (Depending on setting) |
| Construction : |
Outdoor installation type: JIS C0920 Protection class: 3 (rain-proof type)
Installation procedure: 50A pole or wall surface installation
Case: Aluminum alloy casting (Paint color: DIC G-262 or equivalent)
Full cover: Polycarbonate (Resin color: DIC G-262 or equivalent)
Hood: SUS304 (Paint color: DIC G-262 or equivalent, or DIC PART2 2600 or equivalent)
Mount fittings: SUS304 |
| External dimensions : |
222 (W) x 180 (H) x 155 (D) (Mount fittings and protrusion not included) |
| Weight : |
Approx. 4kg |