Product name Carbon Sensor Resistivity Meter
Model HE-960R-GC
Measurement method Electrode type (2-electrode method)
Cell constant Approx. 0.1/cm
Measuring range Measurement unit kΩ·m 0 to 2.00 0 to 20.0 0 to 200.0 0 to 1000 *
MΩ·cm 0 to 0.200 0 to 2.00 0 to 20.00 0 to 100.0 *
*: Measurable without temperature compensation
Temperature: 0°C to 100°C (Select your desired decimal point from 0, 1, and 2 digits.)
Repeatability Within ±0.5% of the full scale (in equivalent input)
Linearity Within ±0.5% of the full scale (in equivalent input)
Transmission
output
4 mA to 20 mA DC: input/output isolated type
Maximum load resistance: 900Ω
Transmission output range: Freely selectable within the measurement range
Contact output Outputs: 2 points
Alarm contact output (R1 and R2)
Calibration function Specific resistance
Temperature
Transmission
output hold feature
· Previous value hold
· Optional value hold
· Continuous
Selectable from the above (However, only the previous value hold is available in the maintenance Mode.)
Self-diagnosis
function
· Sensor diagnosis
· Out of the measurement range
· A/D converter scale over
· Converter error
Temperature
compensation
· Based on the temperature characteristics of extra deionized water (reference temperature:25°C)
· Based on the reference temperature and user-defined temperature coefficient (reference temperature: 5°C to 95°C)
· No temperature compensation
Temperature - compensated range 0°C to 100°C
Extra deionized water specific resistance selection Measurement unit kΩ·m 182.3 (standard), 181.8, 182.4 Select from options shown on the left.
MΩ·cm 18.23 (standard), 18.18, 18.24
Clipping function When the measured value is above the upper limit of the measurement range derived from the specified specific resistance, the specified resistance is used as the measured value.
Temperature compensation element Platinum resistance 1000Ω/0°C
Power supply Rated voltage 24V DC 5W(max)
Structure Indoor-use panel installation type
Panel: IP65 dust and water proof structure
Protective structure Panel: IP65 (IEC60529, JIS C0920)
Conforming standards CE Marking
FCC Rule
External
dimensions
96(W) mm x 96 (H) mm x 115 (D) mm
Case depth: approx. 105 mm (when panel-mounted)
Mass Approx. 500 g
Compatible
sensors
ERF-series specific resistance GC sensor, cell constant 0.1/cm

Related Info
Products

For Semiconductor / LCD Manufacturing Processes Water Quality Meters
Carbon Sensor Resistivity Meter HE-960R-GC
Conductivity Meter / Resistivity Meter

To download catalogues, user registration is required.

Products


2-Channel
Resistivity Meter
HE-960RW
he-960rw
Achieve the advanced control of ultra-pure water, which is optimum for production of ultra-pure water
2 Channel Semiconductor
ultra-pure water IP65

Resistivity Meter
HE-480R
Resistivity meter for ultra-pure water process HE-480R
Highly functional device compatible with a wide range of applications from management of boiler water to semiconductor ultra-pure water.
Semiconductor
Ultra-Pure Water
Wet Rinse IP65

IPA Resistivity Meter
IP-960
IPA Resistivity Meter IP-960
This meter enables IPA to be controlled to high purity to maintain and enhance the performance of IPA vapor (vapour) drying systems.
Semiconductor Wet

 
TOP
Copyright (C) 2008 HORIBA ADVANCED TECHNO,Co.,Ltd. All rights reserved.

Copyright © 2008 HORIBA ADVANCED TECHNO,Co.,Ltd. All rights reserved. The information shown on this document may be modified without notice. Refer to the original web page for update. The page was copied from:
 
Explore the future HORIBA Advanced Techno